Klinger Piston Valves
The Kinger Piston Valves are designed for automation using
electro-mechanic or pneumatic actuators. They are reliable, leak-tight shut off
and align in line and to the atmosphere. And because of its unique robust
construction principle, it has excellent regulation of flow which make it
durable and hence optimized life cycle costs. Most importantly, it is
maintenance free due to its slightest emissions (TA-Luft, EPA) which lead to
increase plant efficiency and reduce loss of operating media.
There are 3 main types of Kinger Piston Valves and they
are KVN, KVMN and KVSN. The Kinger Piston Valves are
widely used in many operating media, for example in the following areas:
- Steam and superheated water
- Miscellaneous types of gases which include Oxygen,
Hydrogen, Nitrogen and etc.
- Heat transfer oils
- Chemicals
Fields of Application:
- District heating
- Energy producing
- Refinery
- Steel production
- Petrochemical
- Chemistry
- Production of tobacco
- Food and beverage
- Pulp and paper
Important Note Regarding Operating Limits:
Please note that the maximum operating temperature of each KLINGER piston valve
depends on the respective operating pressure as well as on the materials of
body or sealing. The pressure and temperature limits are shown in the
P-/T-diagrams.
Klinger material code (m.c.):
Klinger
Material Code |
Body |
Bonnet |
Internal parts
|
Colour, surface
treatment: DN 10-50 |
Colour, surface
treatment: DN 65-200 |
| III |
Grey cast iron |
Grey cast iron |
Without non-ferrous
metal |
Black, phosphated
(grey type plate) |
Grey painted |
| VI |
Spheriodal cast
iron |
Speriodal cast
iron |
Without non-ferrous
metal |
Black, phosphated
(green type plate) |
Green painted |
| VIII |
Cast carbon steel |
Cast carbon steel |
Without non-ferrous
metal |
Black, phosphated
(blue type plate) |
Blue painted |
| Xc |
Stainless steel, acid
resistant |
Stainless steel, acid
resistant |
Stainless steel |
Blanc, pickled (grey
type plate) |
Blanc, pickled |
Flow characteristic values:
| Product type
KVN |
| DN |
10 |
15 |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
| kV |
2 |
4,5 |
8 |
12,5 |
20,5 |
32 |
50 |
69 |
104 |
163 |
233 |
335 |
582 |
| ς |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
6 |
7,2 |
7,2 |
7,2 |
kV...Specific
value for flow rate (m3/h) ò...Resistance value The indicated values
have an accuracy of ±10% and are valid for the fluid water with a